Generic Standards for the Industrial Environment


Generic emission (EN 50081-2) and immunity (EN 50082-2) standards : Industrial environment

EN 50081-2 Emission tests :

  • Enclosure : radiated emission from 30 to 1000MHz as per EN 55011.
  • AC main port : conducted emission from 150kHz to 30MHz as per EN 55011; discontinuous interference appearing often more than 5 time per minute must comply with EN 55014.

EN 50082-2 Immunity tests :

  • Enclosure : radiated RF field from 80MHz to 1000MHz AM modulation as per ENV 50140 at 10V/m and at 900 +/-5MHz with PM modulation as per ENV 50204 at 10V/m; electrostatic discharge as per EN 61000-4-2 at 8kV (air discharge) and 4kV (contact discharge); magnetic field at 50Hz as per EN 61000-4-8 at 30A/m only to apparatus containing devices susceptible to magnetic field.
  • All I/O and main ports : Electric fast transient 5/50ns common mode as per IEC 801-4 (1988), amplitude 1 or 2kV dependent on port type and method of coupling; conducted RF disturbance as per ENV 50141 at 10V.