Generic Standards for the Industrial Environment




Generic emission (EN 50081-2) and immunity (EN 50082-2) standards : Industrial environment.

EN 50081-2 Emission tests :

  • Enclosure : radiated emission from 30 to 1000MHz as per EN 55022 Class B; applicable only to apparatus containing processing devices operating above 9kHz.
  • AC main port: conducted emission from 150kHz to 30MHz as per EN 55011 Class B; discontinuous interference appearing often 5 time per minute must comply with EN 55014.

EN 50082-2 Immunity tests :

  • Enclosure : Radiated RF field from 80MHz to 1000MHz AM modulation as per ENV 50140 10V/m and at 900All I/O and main ports : Electric fast transient 5/50ns common mode as per IEC 801-4 (1988), amplitude 1 or 2kV dependent on type port and method of coupling; conducted RF disturbance as per ENV 50141 at 10V.