Table 1 - Immunity - Enclosure Port
Environmental Phenomena |
Test Specification |
Basic Standard |
Test set-up |
Remarks |
Performance Criteria |
Radio-frequency electromagnetic field |
27 - 500MHz 3V/m (unmodulated) |
IEC 801-3 (1988) |
IEC 801-3 (1988) |
. |
A |
Electrostatic discharge |
8kV (charge voltage) Air Discharge |
IEC 801-2 (1984) |
IEC 801-2 (1984) |
. |
B |
Table 2 - Immunity - Ports for signal lines and control lines
Environmental Phenomena |
Test Specification |
Basic Standard |
Test set-up |
Remarks |
Performance Criteria |
Fast transients common mode |
0.5 kV (peak) 5/50 Tr/Th ns Rep. 5 frequency kHz |
IEC 801-4 (1988) |
IEC 801-4 (1988) Capacitive clamp |
Note 1 |
B |
Note 1 : Applicable only to ports interfacing with cables whose total length according to the manufacturers functional
specification may exceed 3m.
Table 3 - Immunity - Input and output DC power ports
Environmental Phenomena |
Test Specification |
Basic Standard |
Test set-up |
Remarks |
Performance Criteria |
Fast transients common mode |
0.5 kV (peak) 5/50 Tr/Th ns Rep. 5 frequency kHz |
IEC 801-4 (1988) |
IEC 801-4 (1988) |
Note 2 |
B |
Note 2 : Not Applicable to input ports intended for connection to dedicated non-rechargeable supplies.
Table 4 - Immunity - Input and output AC power ports
Environmental Phenomena |
Test Specification |
Basic Standard |
Test set-up |
Remarks |
Performance Criteria |
Fast transients common mode |
1 kV (peak) 5/50 Tr/Th ns Rep. 5 frequency kHz |
IEC 801-4 (1988) |
IEC 801-4 (1988) |
. |
B |
|