EN 50082-1




Table 1 - Immunity - Enclosure Port

Environmental Phenomena Test Specification Basic Standard Test set-up Remarks Performance Criteria
Radio-frequency electromagnetic field 27 - 500MHz
3V/m (unmodulated)
IEC 801-3 (1988) IEC 801-3 (1988) . A
Electrostatic discharge 8kV
(charge voltage)
Air Discharge
IEC 801-2 (1984) IEC 801-2 (1984) . B



Table 2 - Immunity - Ports for signal lines and control lines

Environmental Phenomena Test Specification Basic Standard Test set-up Remarks Performance Criteria
Fast transients common mode 0.5 kV (peak)
5/50 Tr/Th ns Rep.
5 frequency kHz
IEC 801-4 (1988) IEC 801-4 (1988) Capacitive clamp Note 1 B

Note 1 : Applicable only to ports interfacing with cables whose total length according to the manufacturers functional specification may exceed 3m.



Table 3 - Immunity - Input and output DC power ports

Environmental Phenomena Test Specification Basic Standard Test set-up Remarks Performance Criteria
Fast transients common mode 0.5 kV (peak)
5/50 Tr/Th ns Rep.
5 frequency kHz
IEC 801-4 (1988) IEC 801-4 (1988) Note 2 B

Note 2 : Not Applicable to input ports intended for connection to dedicated non-rechargeable supplies.



Table 4 - Immunity - Input and output AC power ports

Environmental Phenomena Test Specification Basic Standard Test set-up Remarks Performance Criteria
Fast transients common mode 1 kV (peak)
5/50 Tr/Th ns Rep.
5 frequency kHz
IEC 801-4 (1988) IEC 801-4 (1988) . B